DONGGUAN HUAXIAN LTD.

Professional Manufacturer of Vacuum Cooler, Ice Machine, Cold Room

Manufacturer from China
Active Member
2 Years
Home / Products / Compressor Condensing Unit /

Outdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In Freezer

Contact Now
DONGGUAN HUAXIAN LTD.
City:dongguan
Province/State:guangdong
Country/Region:china
Contact Person:MissHuya Ye
Contact Now

Outdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In Freezer

Ask Latest Price
Video Channel
Brand Name :HUAXIAN
Model Number :HX
Certification :ISO
Place of Origin :CHINA
MOQ :1 set
Price :USD2000~5000/set
Supply Ability :100sets/month
Delivery Time :30 work days
Packaging Details :Wooden package
Name :Compressor condenser unit
Capacity :10HP
Shape :Box type
Cooling type :Air cooled
Power supply :380V/50Hz/3Phase or recommend
Component :Compressor, condenser, pressure controller, etc
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Box Type Outdoor Compressor Condensing Unit For Walk In Freezer

The refrigeration compression condensing unit is composed of one or several refrigeration compressors, oil separators, condensers, liquid receivers (if necessary), dry filters and accessories. Used to compress and liquefy refrigerants. Commonly used in cold storage.

How to maintain the compression condensing unit:

1. Regularly check the compressor of the air-cooled condensing unit
The compressor is the "heart" of the air-cooled compression condensing unit. Its quality directly affects the stability of the air-cooled compression condensing unit. If the compressor fails to repair, the cost is relatively high, especially the price of the compressor. Therefore, if you hear abnormal sound from the compressor or other conditions, you must contact the air-cooled compressor condensing unit factory to find a professional engineer to check, find out the cause and perform repairs.

2. Regularly clean the condenser and evaporator of the air-cooled compression condensing unit
The condenser/evaporator is the second most important component of the air-cooled compression condensing unit and should be cleaned every six months. The cooling water of the water-cooled condenser is an open circulation loop. The tap water used is recycled through the cooling water tower. It is easy to decompose and deposit impurities to form scale on the water pipe, which affects the heat transfer effect. Excessive scaling will also reduce the circulation section of cooling water, reduce the amount of water, and increase the condensation pressure. Therefore, when the quality of the tap water used is poor, it should be cleaned at least once a year to remove the scale in the pipe and perform water treatment operations on the tap water.

3. Regularly check the chilled water unit passing through the safety valve
The condenser and evaporator of the air-cooled compression condensing unit belong to their own pressure and container. According to relevant regulations, a safety valve should be installed on the high-pressure end of the air-cooled compression condensing unit, that is, the condenser body. Once the unit is in an abnormal condition In the working and living environment, the safety valve can realize automatic pressure relief to prevent damage and loss caused by high pressure.

4. Regular replacement
The air-cooled compression condensing unit uses lubricating oil. After the air-cooled condensing unit is used for a long time, the oil quality of the lubricating oil will deteriorate, and the impurities and moisture in the oil will increase. The oil quality should be observed and checked regularly. Once a problem is found, it should be replaced in time. The brand of lubricating oil to be replaced is subject to the original manufacturer.

5. Regularly replace the drying filter of the air-cooled compresser condensing unit
The dry filter is an important component to ensure the normal development cycle of the refrigerant. Since water and refrigerant are incompatible with each other, if a system contains water, it will greatly affect the operating efficiency of the air-cooled compression condensing unit. Therefore, internal control of drying is very important, and the filter element inside the drying filter must be replaced regularly.


Components

No. Name Brand
1 Compressor BITZER, COPELAND, REFCOMP, HANBELL, etc
2 Condenser KAILAILI or YONGQIANG
3 Filter DANFOSS
4 Ball valve DANFOSS
5 Solenoid valve DANFOSS
6 Sight glass DANFOSS
7 Pressure controller DANFOSS
8 Pressure gauge REFCO


Product Picture for Reference

Outdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In Freezer

Outdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In Freezer

Outdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In FreezerOutdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In FreezerOutdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In FreezerOutdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In Freezer


Successful Case

Outdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In FreezerOutdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In Freezer

Outdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In Freezer


FAQ:

1.Can the refrigeration unit be customized?

  • Yes. The refrigeration unit (compressor condenser unit) can be customized according to customer's requirement.

2.Can the refrigeration unit be made single phase?

  • Yes. But the max compressor for single phase is 3HP. More than 3HP, it should be 3 phase.

3.Can the refrigeration unit be place outdoor?

  • Yes. Our compressor condenser unit is box type. We still recommend building a shed for it, which will keep it safe from severe weather.

4.How's the package of shipment?

  • The compressor condenser unit is packaged by wooden frame for safety shipment.

5.What's the payment terms?

  • By T/T, 30% deposit, 70% will be paid before shipment.

6.What's the lead time?

  • The production lead time is 30 working days, plus 30 days shipping time. Some countries will be longer for sailing.

Inquiry Cart 0